Mediana M30 Multi-Parameter Patient Monitor
Cevi Med#: CM9085
$1,999.00 - $2,460.00
- Condition:
- New
- Availability:
- 7-10 Business Days
- Estimated Shipping Date:
- ...
- Warranty Information:
- 2 Years
- Shipping:
- Free Shipping
Mediana M30 Multi-Parameter Patient Monitor
- Compact and major parameter monitor for portable environment with ECG/Resp, NiBP, Spo2, Ich.Temp, Main or side stream EtCo2 (Option)
- 8.5 TFT LCD display with 3 traces
- ECG: Arrhythmia, S-T segment detection
- 96 hours of graphical and tabular trend with 20 sec recoding time interval
- Lange number display available for all parameters
- Various rechargeable battery options of Li-ion Battery
- Ergonomic handle design for portable grip and patient bedrail installation
- MEDIANA or Nellcor OXIMAX Spo2 technology
- USB port for S/W update and trend download.
Warranty: 2 Years.
Options:
Option | # |
Standard (No Printer) - ECG, respiration, NIBP, SpO2, and Temperature. | M30M-1NXAH |
With Printer - ECG, respiration, NIBP, SpO2, Temperature, and Printer. | M30M-1PNXAH |
Specifications:
- Dimensions: 250 mm (H) x 210 mm (W) x 170 mm (D).
- Weight: 6.6 lbs (3 kg).
- Display: 800 x 480 pixel resolution.
- Electrical:
- Power Requirements: AC 100 ~ 240 VAC, 50/60 Hz, 63 ~ 110 VA / DC power input 11 ~ 15 V.
- Battery: Rechargeable Li-ion.
ECG:
- Measurement Rate: 0, 20 to 300 BPM.
- Accuracy: ± 1 BPM or ± 1%, whichever is greater.
- Leads: 3 / 5 Lead, detected automatically. Lead I, II, III, aVR, aVL, aVF, Chest (V) Lead.
- Display Sweep Speeds: 12.5 mm/sec, 25.0 mm/sec, and 50.0 mm/sec.
ST Segment:
- Measurement Range: -2.0 mV ~ 2.0 mV.
- Alarm Range: -2.0 mV ~ 20.0 mV.
- Arrhythmia Analysis: Yes.
Respiration Rate:
- Method: RA to LA Impedance.
- Range: 0, 3 to 120 breaths/min.
- Accuracy: ± 3 breaths/min.
- Display Sweep Speeds: 6.25 mm/s, 12.5 mm/s, 25.0 mm/s.
NIBP:
Pulse Rate Range:
- Adult/Pediatric: 40 to 200 BPM.
- Neonatal: 40 to 240 BPM.
- Pulse Rate Accuracy: ± 2 BPM or ± 2%, whichever is greater.
- Technique: Oscillometric Measurement.
- Operation Mode: Manual, Auto, Continuous.
Pressure Display Range:
- Adult/Pediatric: 0 - 300 mmHg.
- Neonatal: 0 - 150 mmHg.
SpO2:
- Range: 0 - 99%.
- Accuracy: 70 - 99 ± 2 digits (adult/pediatric/neonate).
- Pulse Rate: 30 to 254 BPM with resolution 1 BPM.
- Display Sweep Speeds: 12.5 mm/s, 25.0 mm/s, 50.0 mm/s.
Temperature:
- Channels: 1.
- Range: 32 to 122 °F (0 to 50 °C) selectable.
Trends:
- Display Interval: 20 sec, 1 min, 2 min, 3 min, 5 min, 10 min.
- Trend Store Data: EtCO2, lnCO2.
Literature