Masimo Oridion Capnostream 20 with Printer 16245
Cevi Med#: CM8937
$6,955.00
MSRP:
$7,300.00
- Condition:
- New
- Availability:
- 7-10 Business Days
- Estimated Shipping Date:
- ...
- Warranty Information:
- 1 Year
- Shipping:
- Free Shipping
Masimo Oridion Capnostream 20 with Printer
- Easy to use rotary dial selector for simple navigation of the device.
- non-invasive method for monitoring the level of carbon dioxide in exhaled breath (EtCO2)
- provides accurate and reliable assessments for all patient types.
- reduce clinically insignificant alarms by 53% with the Oridion Smart Capnography SARA algorithm.
- Large, bright color display with an easy-to-use, knob-navigated, flat-menu structure
- Providing CO2 and SpO2 measurements.
- Transfer patient data to USB flash memory devices
- 72-hour trends to review
- Can use in other laboratory environments
- Case recording to help organize patient files.
- RS-232 port for data transfer.
- If power is lost , automatically switched to the internal battery pack for power
Warranty: 1 Year.
Specifications
- Power:Input Voltage: 100 - 240 VAC, 50/60 Hz.
- Power: Fuses: Two F3.15A 250 Volt.
- Power:Input Power: 90 VA.
- Battery:Battery Type: 14.8 V, 4Ah Lithium-Ion.
- Battery:Battery Operation: 2.5 hours (without thermal recorder).
- Battery: Battery Charging Time: 100% in 12 hours.
- Screen: 6.4" (162 mm) color TFT display.
- Screen Resolution: 640 x 480 pixels.
- Trace Speed: 3.0, 6.3, 12.5, and 25 mm / second.
- Waveform Sampling Rate: 75.7 samples / second for SpO2; 20 samples / second for Capnography.
- Trend Storage: 8640 point storage.
- CO2, EtCO2, FiCO2 Range: 0 - 99 mmHg.
- CO2 Waveform Resolution: 0.1 mmHg.
- EtCO2, FiCO2 Resolution: 1 mmHg.
- CO2 Accuracy: 0 - 38 mmHg: ± 2 mmHg.
- CO2 Accuracy: 39 - 99 mmHg: ± 5% of reading + 0.08% for every 1 mmHg above 38 mmHg.
- Respiration Rate Accuracy: 0 - 70 bpm: ± 1 bpm.
- Respiration Rate Accuracy:71 - 120 bpm: ± 2 bpm.
- Respiration Rate Accuracy :121 - 150 bpm: ± 3 bpm.
- Flow Rate: 50 ml/minute, flow measured by volume.
- Waveform Sampling: 20 samples / second.
- Response Time: 2.95 seconds (typical).
- Initialization Time: 40 seconds (typical).
- Calibration Interval: Initially calibrate after 1,200 operating hours, then once a year or after 4,000 operating hours, whichever comes first.
- SpO2 Measurement Range: 1 - 100%.
- SpO2 Range:Adult Mode 0 - 69%: Unspecified.
- SpO2 Range: Adult Mode 70 - 100%: ± 2 digits.
- SpO2 Range: Neonate Mode 0 - 69%: Unspecified.
- SpO2 Range: Neonate Mode 70 - 100%: ± 3 digits.
- Pulse Rate Range: 25 - 240 bpm.
- Pulse Rate Accuracy: No Motion Conditions: ± 3 digits.
- Pulse Rate Accuracy: Motion Conditions: ± 5 digits.
- Perfusion Index Range: 0.02 - 20%.
Product | Condition |
Masimo Oridion Capnostream 20 with Printer |
New |
Literature
1 Year