Edan F9 Express Fetal-Maternal Monitor
Cevi Med#: CM8749
$9,600.00
MSRP:
$10,200.00
- Condition:
- New
- Availability:
- 7-10 Business Days
- Estimated Shipping Date:
- ...
- Warranty Information:
- 2 Years
- Shipping:
- Free Shipping
Edan F9 Express Fetal-Maternal Monitor
F9 is high-end fetal & maternal monitor, it offers the most advanced integrated monitoring for the delivery room in big hospital, private obstetrician's office, antepartum clinic. F9, designed for moving situations, covers the entire continuum of antepartum, intrapartum and postpartum applications.
Warranty: 2 Years
Included:
Product | Number |
2 FHR Probes | 12.01.109301-01 |
TOCO Probe | 12.01.31527-01 |
3 lead ECG Cable . | 01.57.471007 |
Adult Disposable Adhesive Electrodes [(Snap Connector) | 11.57.040159 |
3 m NIBP Tubing . | 01.59.036104 |
Reusable Adult Cuff [(25 - 35 cm). | 11.57.40029 |
Temperature Skin Probe | 01.15.040187 |
Event Marker | 02.01.210095 |
Patient Belt | 01.57.02264 |
Ultrasound Gel [(CE Mark, 250 g) | 11.57.78008-11 |
Edan SH1 Reusable SpO2 Sensor | 12.01.109069 |
1 Packet Recording Paper | F6/F9-P |
Ethernet Cable | 11.13.20096 |
Insight Connection Cable |
01.13.107659-11 |
Insight Software (CD) and Manual. | # |
User manual | # |
Features :
- Basic parameters: FHR, TOCO, Event Mark, AFM
- Included Maternal parameters: ECG, HR/PR, NIBP, SpO2, Temperature
- 24 hours waveforms playback
- Optional Built-in wireless module
- Software for data transmission to PC
- 150/152mm wide paper
- Support US/International standard paper
- 1,2,3cm/min real-time printing speeds
- Quick printing for stored waveform
- Lithium battery for 4 hours continuous working
- 12.1- inch high-resolution color folding up LCD touch-screen
- Probe rack and wall mounting rack
- Handle for easy carry
- 12 - crystal pulse wave Doppler water-proof transducer for FHR detection
- Signal Overlap Verification
Specifications:
Physical Characteristics
Physical Characteristics
- Dimensions: 347mm x 330mm x 126mm
- Weight: 6 kg. approx.
- 10.2 inches color TFT-LCD
- Resolution: 800 (H) x 600 (H)
- Recorder: 1,2,3/cm./min. real printing speed. Fast print speed (stored traces) up to 25mm/sec.
- Paper: Z-Fold, thermosensitive
- 14.8 V rechargable Lithium-ion battery
- Continuous Working Time: 4 Hours
Ultrasound
- Technique: Ultrasound Pulse Doppler with auto-correlation
- Pulse repetition rate: 2 KHz
- Ultrasound frequency: 1.0MHz ± 10%
- FHR range: 50bpm - 240bpm
- Resolution: 1bpm
- Accuracy: ±2 bprn
DECG
- Technique Peak - Peak detection technique
- FHR range: 30 bpm- 240bpm (American Standard), 50bpm-210 bpm (International Standard)
- Resolution: 1bpm
- Accuracy: ±1bpm
- Input Impedance: >10M
- Input Impedance: >20M (Common Mode)
TOCO
- TOCO Range: 0-100 Relative (%)
- Resolution: 1%
- Zero mode: Auto/Manual
- Non-Linear error: ±1 mmHg
- Pressure range: 0-100 mmHg
- Resolution: 1%
- Zero mode: Auto/Manual
- Non-Linear error: ±1 mmHg
- Technique: Pulsed Doppler Ultrasound
- Range: 0-100 (%)
- Resolution: 1%
- Manual fetal movement mark
- Measuring range: 0-100 Relative (%)
- Resolution: 1%
- Measuring accuracy: 90-100% ±1 2%, 70%-90% ±4%
PR
- Measuring range: 30bpm-240bpm
- Measuring accuracy: ±2bpm
NIBP
- Systolic Pressure: 50mmHg - 240mmHg
- Mean Pressure: 25mmHg - 200mmHg
- Diastolic Pressure: 15mmHg - 180mmHg
- Resolution: 1mmHg
Temperature
- Systolic Pressure: 50mmHg - 240mmHg
Warranty Information
- 2-Year Warranty
Literature
2 Years