Skip to main content

ADC Adstation 56122-56 3.5V Wall Coax Plus Ophthalmoscope/Throat Illuminator/Dermascope Diagnostic Set

(No reviews yet)  |  Write a Review
Icon of shipping box.

Delivery by Cevi Med

Learn More
Icon of shipping box.

Price Match Guarantee

Learn More
Icon of shipping box.

Purchase Order

Learn More
Icon of shipping box.

Sales Tax Exemption

Learn More
Note:This item will be shipped using our internal delivery service instead of FedEx.

Check out the deliveries we have made in the U.S.A.

Here is a digital portfolio deliveries and installations done by us across the United States. Select a state to see pictures from clinical offices, hospitals, and medical universities in your area.

What Do Our Customers Say About Us??

$0.00
MSRP: $1,200.00
Condition:
New
Availability:
5-7 Business Days
Estimated Shipping Date:
...
Warranty Information:
<li> 5 Years (Wall Transformer), 2 Years (Instrument Head and Xenon Lamps), Lifetime (LED Lamp).
Shipping:
$10.00

Icon of shipping box.

Delivery by Cevi Med

Learn More
Icon of shipping box.

Price Match Guarantee

Learn More
Icon of shipping box.

Purchase Order

Learn More
Icon of shipping box.

Sales Tax Exemption

Learn More
Note:This item will be shipped using our internal delivery service instead of FedEx.

Check out the deliveries we have made in the U.S.A.

Here is a digital portfolio deliveries and installations done by us across the United States. Select a state to see pictures from clinical offices, hospitals, and medical universities in your area.

What Do Our Customers Say About Us??

About this item

ADC Adstation 56122-56 3.5V Wall Coax Plus Ophthalmoscope/Throat Illuminator/Dermascope Diagnostic Set

The ADC Adstation 56122-56 3.5V Wall Coax Plus Ophthalmoscope/Throat Illuminator/Dermascope Diagnostic Set includes an ADC Diagnostix 5442 3.5V Coax Plus Ophthalmoscope Head, an ADC Diagnostix 5426 3.5V Throat Illuminator Head, an ADC Diagnostix 5450 3.5V Dermascope Head, a power supply base unit that includes a power switch, three 3.5V handles, and two extension modules. The wall transformer is available with a standard 120V or a 230V power supply with European plug in, and is easy to install with the included bracket or it may be mounted to ADC wallboard systems. The ophthalmoscope and throat illuminator heads are available with a halogen/xenon lamp or an advanced AdLED lamp. The ADC Diagnostix 5450 3.5V Dermascope Head uses AdLED illumination.

The ADC Diagnostix 5442 3.5V Coax Plus Ophthalmoscope Head is intended to examine the media (cornea, aqueous, lens, and vitreous) and the retina of the eye. The ADC Diagnostix 5426 3.5V Throat Illuminator Head is designed for examination of the oral cavity and pharynx in combination with commercial wooden and plastic blades, and the ADC Diagnostix 5450 3.5V Dermascope Head is produced for early identification of changes of skin pigmentation (malignant melanomas).

 

Warranty: 

      • 5 Years (Wall Transformer)
      • 2 Years (Instrument Head and Xenon Lamps)
      • Lifetime (LED Lamp)

 

Diagnostix 5442 3.5V Coax Plus Ophthalmoscope Head Features:

      • High performance aspherical condenser lens reduces corneal reflection.
      • Further reduction provided by utilizing distinct parallel observational and illuminating light beam. (Gullstrand’s principal).
      • Ergonomic design and integral thumb rest improves stability and allows one finger control of all functions.
      • Synthetic rubber brow rest facilitates use with practitioner eyeglasses.
      • Dust proof.
      • Magnified/illuminated aperture viewing window.
      • Universal bayonet mount for compatibility with other brands of 3.5V power supply handles.
      • Anti-theft locking feature is standard.
      • Secondary Focusing wheel with zero retention for quick correction of ametropias. Use this to provide virtually unlimited fine focus OR as a fast focus in lieu of the 89 viewing lenses.
      • 89 viewing lenses - Plus single step from 1-45. Minus single step from 1-44.
      • 28 aperture/filter combinations for improved versatility.

 

7 apertures include:

      • Karo – grid like overlay that allows for easier transfer of observations to standard Karo (graph) paper.
      • Slit – used to help determine levels of tumors and lesions.
      • Fixation - has graduated cross-hairs for measuring eccentric fixation or locating lesions.
      • Large - standard aperture for a dilated pupil and general examination of the eye.
      • Small - provides excellent view of fundus through an undilated pupil.
      • Micro spot - allows quick entry into small, undilated pupils.
      • Half moon – provides a combination of depth perception and field of view.

 

3 filters (plus neutral) include:

      • Red free - excludes red rays from examination field for easy identification of veins, arteries and nerve fibers.
      • Cobalt - used with fluorescent dye to view small lesions, abrasions and foreign objects on the cornea.
      • Polarizing – virtually eliminated corneal reflection.

 

Diagnostix 5426 3.5V Throat Illuminator Head Features:

      • PMMA light transmission (similar to Fiberoptic) for unobstructed view of oral cavity.
      • Tongue blade holder facilitates examination of the mouth and throat.
      • Eject button discards used tongue blade.
      • Universal bayonet mount for compatibility with other brands of 3.5v power supply handles.
      • Anti-theft locking feature is standard.

 

Diagnostix 5450 3.5V Dermascope Head Features:

      • Direct Illumination.
      • Optical grade 10X focusable magnifying lens.
      • Large knurled focusing ring.
      • Two interchangeable contact plates – one with scale, one without may be disinfected.
      • Comfortable soft eyepiece may be used with eyeglasses.
      • Anti-theft locking feature is standard.
      • AdLED illumination.

 

Wall Transformer Power Supply Features:

      • Magnetic switch activates power when handle is removed from cradle, automatically powers off when handle is replaced.
      • Handle is CNC machined from solid brass and chrome plated in black with a ribbed surface for a sure grip.
      • Adtronic electronic rheostatic light intensity control provides infinite continuous control.
      • Adtronic auto-off feature after two minutes provides additional safety if instrument is mis-cradled.
      • Bayonet instrument mount is compatible with all major brands of 3.5V instrument heads.
      • Base unit contains the power switch and one handle and the extension holds the other handle.
      • One additional extension module can be added.
      • UL approved.

 

Configurations:

      • Xenon Ophthalmoscope/Xenon Throat Illuminator/LED Dermascope (56122X-56X)
      • LED Ophthalmoscope/LED Throat Illuminator/LED Dermascope (56122L-56L)
      • Xenon Ophthalmoscope/LED Throat Illuminator/LED Dermascope (56122X-56L)
      • LED Ophthalmoscope/Xenon Throat Illuminator/LED Dermascope (56122L-56X)
      • Xenon Ophthalmoscope/Xenon Throat Illuminator/LED Dermascope European Plug (56122X-56XEU)
      • LED Ophthalmoscope/LED Throat Illuminator/LED Dermascope European Plug (56122L-56LEU)
      • Xenon Ophthalmoscope/LED Throat Illuminator/LED Dermascope European Plug (56122X-56LEU)
      • LED Ophthalmoscope/Xenon Throat Illuminator/LED Dermascope European Plug (56122L-56XEU)

 

Specifications:

      • Diagnostic Station Dimensions: 7.88" x 7.12" x 2.95" (20.02 cm x 18.08 cm x 7.5 cm).
      • Extension Module Dimensions: 7.88" x 3.94" x 2.95" (20.02 cm x 10.01 cm x 7.5 cm).

 

Options and Configurations

Product # Option Pcs/Pkg

56122L-56L

Standard

1/ea

 56122L-56L

Standard

1/ea

 56122L-56X

Standard

1/ea

 56122X-56X

Standard

1/ea

 56122X-56XEU

European

1/ea

 56122L-56LEU

European 1/ea

 56122X-56LEU

European 1/ea

 56122L-56XEU

European 1/ea
  • 5 Years (Wall Transformer), 2 Years (Instrument Head and Xenon Lamps), Lifetime (LED Lamp).